  SLX 9140 Switch Specifications
Form Factor 1U
Switching Bandwidth (data rate, full duplex) 1.8 Tbps in and 1.8 Tbps out for a sum total of 3.6 Tbps
Forwarding Capacity (data rate, full duplex) (L2) 1.2 Bpps, (L3) 600 Mpps line-rate performance
Dimensions and Weight 44.0 cm; 17.3 in. (Width), 44.5 cm; 17.5 in. (Depth), 4.37cm; 1.72 in. (Height)
9.00 kg; 19.8 lb
Port-to-port latency 2.5 usec
Architecture Store and Forward Supported
25/10/1 GbE ports 48
100/40 GbE Ports 6
Power Supplies Two internal, redundant, field-replaceable, load-sharing AC or DC power supplies
Cooling Fans Five field-replaceable fans
Airflow Rear-to-front or front-to-rear airflow
Dynamically Shared Packer Buffer 24 MB
Power
Power Inlet (AC) C13
Input Voltage 90 V to 264 V or 40.8 V to 60 V DC
Input Line Frequency 47 Hz to 63 Hz
Inrush Current 25 A peak
Maximum Current 12 A/AC, 14 A/D
Typical Power Consumption 182 W | Two AC PSU, five fan trays, 10% traffic, low fan speed
Maximum Power Consumption 489 W | Two AC PSU, six fan trays, 100% traffic, high fan speed
Power Supply Rated Maximum (AC) 650 W
Switch Power Consumption DC PSU 475 W; AC PSU 489 W
Environment
Temperature Operating:
−5°C to 50°C (front-to-back air flow)
−5°C to 45°C (back-to-front air flow)
Temporarily up to 55°C (six fan trays)
Non-operating and storage: −40°C to 70°C
Humidity 5% to 95% at 50°C
Altitude Up to 3,000 m safety; 60 m to 4,000 m operational
Shock (operational) 20 G, 11 ms, half-sine wave
Vibration (operational) 1 G sine, 0.4 gms random, 5 Hz to 500 Hz
Airflow 134 CFM (estimated with two PSU, six fan trays)
Switch heat dissipation (25°C) AC PSU 400 W
Acoustics (25°C) 52 dBA
MTBF (25°C) 324,414 hours
Software Specifications
Connector Options 10/1 GbE SFP+
40 GbE QSFP+
25 GbE SFP-28
100 GbE QSFP-28
Out-of-band Ethernet management: 10/100/1000 Mbps RJ-45
Console management: RJ45 serial port and USB type-C port with serial communication device class support
Storage: USB port, standard-A plug
Maximum MAC Addresses Up to 96,000
Maximum VLANs 4,096
Maximum Routes (in hardware) Up to 80,000
Maximum ACLs 2,000
Maximum Members in a Standard LAG 36
Maximum Per-Port Priority Pause Level 8
Maximum Switches an mLAG Can Span 2
Maximum IPv4 Unicast Routes 48,000
Maximum IPv6 Unicast Routes 16,000
DCB Priority Flow Control Classes 8
Maximum Jumbo Frame Size 10,000 bytes
QoS Priority Queues (per port) 8