Details:
Description
Specification Model Cisco ASR 9006 Cisco ASR 9010
Categories Physical specifications
  • Height: 17.50 in. (444.5 mm) (10 RU)
  • Width: 17.38 in. (441.45 mm)
  • Depth:
    • With doors: 29.05 in. (737.9 mm)
    • Without doors: 29.05 in. (737.9 mm)
  • Weight:
    • 89.55 lb (40.7 kg) (chassis with PEM)
    • 150 lb (65.91 kg) (fully loaded, excluding line cards and power modules) – RSP, two v2 FAN trays, PEMs
  • Height: 36.75 in. (933.45 mm) (21 RU)
  • Width: 17.38 in. (441.45 mm)
  • Depth:
    • With doors: 29.03 in. (737.4 mm)
    • Without doors: 28.24 in. (717.3 mm)
  • Weight:
    • 155.6 lb (70.73 kg) (chassis with PEM)
    • 231.6 lb (105.27 kg) (fully loaded, excluding line cards and power modules) – RSP, two v2 fan trays, PEMs
Slot orientation Horizontal Vertical
Cisco ASR 9000 Series RSP Dual redundant RSPs with integrated fabric in 2 slots Dual redundant RSPs with integrated fabric in 2 slots
Cisco ASR 9000 Series line cards 4 line-card slots 8 line-card slots
“Commons” components
  • 2 RSPs
  • 2 fan trays
  • 1 PEM (either DC or AC)
  • 1 fan filter
  • 2 RSPs
  • 2 fan trays
  • 2 PEMs (either DC or AC)
  • 1 fan filter
Reliability and availability
  • Fabric redundancy
  • Fan redundancy
  • Feed redundancy
  • Power-supply redundancy
  • RSP redundancy
  • Software redundancy
  • Fabric redundancy
  • Fan redundancy
  • Feed redundancy
  • Power-supply redundancy
  • RSP redundancy
  • Software redundancy
Rack mounting
  • 19-in. default
  • 21- and 23-in. adapters available
  • Note: Minimum 17.75-in. opening between posts is needed for proper operation
  • 19-in. default
  • 21- and 23-in. adapters available
  • Note: Minimum 17.75-in. opening between posts is needed for proper operation
Cabinet mounting
  • Yes
  • Note: Doors not recommended in enclosed cabinets
  • Yes
  • Note: Doors not recommended in enclosed cabinets
Wall mounting No No
Airflow Right-to-back, Front-to-back with baffle Front-to-back
Performance Fabric
  • One per RSP:
  • Active/active nonblocking operation mode in dual-RSP redundant configuration
  • Fully redundant in dual-RSP redundant configuration
  • Built-in service-intelligence and traffic-prioritization capability
  • One per RSP:
  • Active/active nonblocking operation mode in dual-RSP redundant configuration
  • Fully redundant in dual-RSP redundant configuration
  • Built-in service-intelligence and traffic-prioritization capability
Thermal
  • Two fan trays:
  • 6 high-efficiency fans per tray
  • Variable-speed fans for optimal thermal performance
  • No single point of failure
  • Two fan trays:
  • 12 high-efficiency fans per tray
  • Variable-speed fans for optimal thermal performance
  • No single point of failure
Power Modularity
  • Pay-as-you-grow power for future scalability, available in AC and DC.
  • Multiple power module types:
    • 3 kW AC power module
    • 2.1 kW DC power module
  • Note: Mixing of AC and DC modules is not supported
  • Pay-as-you-grow power for future scalability, available in AC and DC.
  • Multiple power module types:
    • 6 kW and 3 kW AC power modules
    • 4.4 kW and 2.1 kW DC power modules
  • Note: Mixing of AC and DC modules is not supported
Redundancy
  • AC: N+N redundancy
  • DC: N+1 redundancy
  • Power module redundancy
  • A/B Feed redundancy
  • AC: N+N redundancy
  • DC: N+1 redundancy
  • Power module redundancy
  • A/B Feed redundancy
  • PEM redundancy
Power zones
  • No power zone restrictions
  • Fully load-sharing power infrastructure
  • No power zone restrictions
  • Fully load-sharing power infrastructure
Power input
  • Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum)
  • Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)
  • Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum)
  • Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)
Power-module airflow Front-to-back Front-to-back
Environmental Specifications (All Entries Applicable to Cisco ASR 9006 and ASR 9010) Operating temperature (nominal) 41 to 104°F (5 to 40°C) 41 to 104°F (5 to 40°C)
Operating temperature (short-term) ASR 9006: 23 to 131°F (-5 to 55°C) ASR 9010: 23 to 122°F (-5 to 50°C)
Operating humidity (nominal) (relative humidity) 5 to 90% 5 to 90%
Storage temperature -40 to 158°F (-40 to 70°C) -40 to 158°F (-40 to 70°C)
Storage (relative humidity) 5 to 93% 5 to 93%
Operating altitude -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements) -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Regulatory Compliance (All Entries Applicable to Cisco ASR 9006 and ASR 9010) Network Equipment Building Standards (NEBS)
  • Cisco ASR 9006 and ASR 9010 Routers are designed to meet:
  • SR-3580: NEBS Criteria Levels (Level 3)
  • GR-1089-CORE: NEBS EMC and Safety
  • GR-63-CORE: NEBS Physical Protection
  • VZ.TPR.9205: Verizon TEEER
  • Cisco ASR 9006 and ASR 9010 Routers are designed to meet:
  • SR-3580: NEBS Criteria Levels (Level 3)
  • GR-1089-CORE: NEBS EMC and Safety
  • GR-63-CORE: NEBS Physical Protection
  • VZ.TPR.9205: Verizon TEEER
ETSI standards
  • Cisco ASR 9006 and ASR 9010 Routers are designed to meet:
  • EN300 386: Telecommunications Network Equipment (EMC)
  • ETSI 300 019 Storage Class 1.1
  • ETSI 300 019 Transportation Class 2.3
  • ETSI 300 019 Stationary Use Class 3.1
  • Cisco ASR 9006 and ASR 9010 Routers are designed to meet:
  • EN300 386: Telecommunications Network Equipment (EMC)
  • ETSI 300 019 Storage Class 1.1
  • ETSI 300 019 Transportation Class 2.3
  • ETSI 300 019 Stationary Use Class 3.1
EMC standards emission
  • Cisco ASR 9006 and ASR 9010 Routers are designed to meet:
  • FCC Class 47CFR15 A
  • ICES 003 Class A
  • AS/NZS CISRP22 Class A
  • CISPR 22 (EN55022) Class A
  • VCCI Class A
  • BSMI Class A
  • IEC/EN 61000-3-12: Power Line Harmonics
  • IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
  • EN55022: Information Technology Equipment (Emissions)
  • EN 50121-4: Railway EMC
  • Cisco ASR 9006 and ASR 9010 Routers are designed to meet:
  • FCC Class 47CFR15 A
  • ICES 003 Class A
  • AS/NZS CISRP22 Class A
  • CISPR 22 (EN55022) Class A
  • VCCI Class A
  • BSMI Class A
  • IEC/EN 61000-3-12: Power Line Harmonics
  • IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
  • EN55022: Information Technology Equipment (Emissions)
  • EN 50121-4: Railway EMC
EMC standards immunity
  • Cisco ASR 9006 and ASR 9010 Routers are designed to meet:
  • IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
  • IEC/EN-61000-4-3: Radiated Immunity (10V/m)
  • IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
  • IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
  • IEC/EN-61000-4-5: Signal Surge Ports (1kV)
  • IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
  • IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
  • IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
  • IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
  • EN55024: Information Technology Equipment (Immunity)
  • EN50082-1/EN-61000-6-1: Generic Immunity Standard
  • EN 50121-4: Railway EMC
  • Cisco ASR 9006 and ASR 9010 Routers are designed to meet:
  • IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
  • IEC/EN-61000-4-3: Radiated Immunity (10V/m)
  • IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
  • IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
  • IEC/EN-61000-4-5: Signal Surge Ports (1kV)
  • IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
  • IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
  • IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
  • IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
  • EN55024: Information Technology Equipment (Immunity)
  • EN50082-1/EN-61000-6-1: Generic Immunity Standard
  • EN 50121-4: Railway EMC
Safety
  • Cisco ASR 9006 and ASR 9010 Routers are designed to meet:
  • UL/CSA/IEC/EN 60950-1
  • IEC/EN 60825 Laser Safety
  • ACA TS001
  • AS/NZS 60950
  • FDA Code of Federal Regulations Laser Safety
  • Cisco ASR 9006 and ASR 9010 Routers are designed to meet:
  • UL/CSA/IEC/EN 60950-1
  • IEC/EN 60825 Laser Safety
  • ACA TS001
  • AS/NZS 60950
  • FDA Code of Federal Regulations Laser Safety

CONTACT US TO LEARN MORE